HCTL600KA Flexible Current Probe - High Frequency And Large Current Measurements For Extra Large Power Facilities

  • 1
  • 2

Brand Name : MEASTEK

Model Number : HCTL600KA

MOQ : 1

Payment Terms : T/T,Western Union,MoneyGram

Delivery Time : 5-8 work days

Sensitivity (mV/A) : 0.01

Current (KA) : 600

Maximum noise (mV Vpp) : 2.5

Attenuation characteristics (%/ms) : 0.008

Low frequency bandwidth -3dB(Hz) : 0.01

High frequency bandwidth -3dB(MHz) : 10

Typical accuracy : 1%

Insulation voltage value : 10KV

Contact Now

MEASTEK HCTL600KA Flexible Current Probe - High Frequency And Large Current Measurements For Extra Large Power Facilities


1.Harmonic measurement expertise

With a bandwidth of 10MHz, it can effectively measure harmonics in current, and is often used for current monitoring of super-large generators, helping to optimize power generation efficiency and ensure the stability of power supply.


2. High-precision micro-current measurement

0.01mV/A sensitivity, 1% typical accuracy, can accurately measure micro-current and sine wave micro-phase shift. In the test of super-large power transformers, it can accurately detect current changes to ensure reliable equipment performance.


3. High-voltage and high-current measurement

10KV insulation withstand voltage, suitable for current measurement of super-large power facilities with large current and high voltage, and plays an important role in the construction and operation and maintenance of large-scale power projects.


4. Flexible measurement characteristics

The outer diameter of the induction loop is 8mm, which is soft and flexible, convenient for current measurement in complex wiring of super-large power facilities, adapting to various complex installation environments, and improving the convenience of measurement.


5. Convenient connection and power supply

USB power supply, low insertion loss, standard BNC output interface is convenient for connecting various measuring instruments, meeting the research and development and operation and maintenance test needs of super-large power facilities, and providing convenience for technicians.


6. Customized solutions

The length of the probe ring and the connecting line can be customized according to customer requirements. Customized probes are provided for the special structure and measurement requirements of extra-large power facilities to ensure accurate and efficient measurement.


Specifications

Model HCTL600KA
Sensitivity (mV/A) 0.01
Peak Current (KA) 600

dI/dt(KA/μs)

40
Maximum noise (mV Vpp) 2.5
Attenuation characteristics(%/ms) 0.008
Low frequency bandwidth -3dB(Hz) 0.01
High frequency bandwidth -3dB(MHz) 10
Typical accuracy

1%

Insulation voltage value

10KV


HCT(S)XXXXA Series Other Technical Parameters

Maximum output voltage

6Vpk

Terminal load

≥100kΩ

Power supply mode USB 5V (standard adapter)
Operating temperature range Integrator

0℃ - 50℃

Probe ring

0℃ - 100℃

Storage temperature range

-40℃~80℃


Product Description

HCTL600KA Flexible Current Probe - High Frequency And Large Current Measurements For Extra Large Power Facilities

(Take HCTS0120A as an example)


1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output terminal.
3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

4) Test connection diagram.

HCTL600KA Flexible Current Probe - High Frequency And Large Current Measurements For Extra Large Power Facilities


Mechanical specifications

Model HCTSXXXXA
Typical value of flexible probe circumference (customizable)

80mm

Typical value of induction ring body diameter

1.6mm

Typical value of flexible probe diameter (customizable)

25mm

Induction loop connection cable length 1 M (customizable)
BNC connection cable length 1 M or 2 M, 1 M is Standard

Integrator body dimensions

(including BN port dimensions)

About 110(L)*47(W)*30(H)mm
USB cable (AM-BM) About 1.8m
USB output adapter About 59mm*30mm*20mm
Probe weight About 150g
Box weight (including probe) About 960g


Care And Maintenance

1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


Packing List

Name Quantity
Current probe integrator 1 piece
Current probe flexible induction coil 1 piece
USB output adapter (5V/1A) 1 piece
USB power cable 1 piece
BNC output cable 1 piece
Electronic manual 1 serving



China HCTL600KA Flexible Current Probe - High Frequency And Large Current Measurements For Extra Large Power Facilities wholesale

HCTL600KA Flexible Current Probe - High Frequency And Large Current Measurements For Extra Large Power Facilities Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Knowhow Technology Co.,limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0